MENU list
These are the parameters (items to set) you see when you press the [OCT+] (MENU) button while holding down the [SHIFT] button.
MEMO
If you’re viewing this content on your smartphone, we recommend that you turn your smartphone on its side for landscape mode.
Parameter | Display | Value | Explanation |
---|---|---|---|
Volume (*1) | vOL
| 0–200 | Sets the pattern’s volume. |
Transpose (*1) | trAn | -60–60 | Transposes the sounds made by the sound generator. |
Pattern Scale (*1) | P.SCL | Sets the length of a single step in the pattern. You can also switch between settings by holding down the [PATTERN] button and turning the [TEMPO/VALUE] knob. | |
1_8 | Eighth note | ||
1_16 | Sixteenth note | ||
1_32 | Thirty-second note | ||
8t | Eighth-note triplet | ||
16t | Sixteenth-note triplet | ||
32t | Thirty-second-note triplet | ||
Play Quantize (*1) | P.qnt | This enables or disables the sample pad quantize settings that are used when a pattern is played. MEMO The micro-timing setting is disabled for sample pads whose quantize setting is enabled. Refer to “Editing notes” for details on micro-timing. | |
ALL | Sets the quantization for all sample pads (including the [GRANULAR] pad).
| ||
A-1–H-6, Grnu (Granular) | Sets the quantization for each of the specified sample pads (including the [GRANULAR] pad).
| ||
Quantize Timing | qnt.t | 50–99 (%) | Sets the timing for quantization, meaning whether to align the note with the current step, or to align it with the next step. When this is set to 50%, any notes you input that are 50% or later than the length of one step are aligned with the next step, meaning that they play on the next step. Higher values increase the range of notes that are aligned to the current step. |
Stop Behavior | StoP | This sets how the sample stops when the pattern sequencer is stopped. This also sets how the sample stops that was playing just before you switch the pattern that’s currently playing to a different pattern (available from Ver. 1.02 or later). | |
rE÷n (Remain) | The playback of the sample does not stop. | ||
Cut (Cut) | The playback of the sample stops. | ||
Sync Clock | S.cLk | 1, 2, 3, 4, 6, 8, 12, 24 | Sets the number of sync clocks per beat. |
Sampler MIDI Channel | S.CH | 1–16 | Sets the MIDI transmit/receive channel for the sample pads [1]–[6]. |
Granular MIDI Channel | G.CH | 1–16 | Sets the MIDI transmitting/receiving channel for the [GRANULAR] pad. |
Auto MIDI Channel | A.CH | 1–16 | This is the MIDI receive channel used for playing the currently selected pad (sample pads [1]–[6], [GRANULAR] pad) or receiving control change messages. |
MIDI Clock Sync | SYnC | Sets which synchronization signal (clock) this unit follows. Note that when an external device is connected to the SYNC IN jack, the unit always synchronizes to the sync signals that are input from the SYNC IN jack. | |
AUtO (Auto) | Inputted clocks are accepted. | ||
Int (Internal) | The unit operates according to its internal clock. | ||
÷iDi (MIDI) | Clocks are accepted via the MIDI IN connector. | ||
USb (USB) | Clocks are accepted via the USB MIDI connector. | ||
MIDI Thru | thrÜ | OFF, On | Specifies whether to output the MIDI messages to the MIDI OUT connector that are input to the MIDI IN connector. |
Tx Program Change | txPc | OFF, On | Sets whether program change messages are transmitted or not when the pattern changes. |
Rx Program Change | rxPc | OFF, On | Sets whether the pattern changes when a program change message is received. |
Program Change Channel | Pc.Ch | 1–16 | Sets the MIDI channel for transmitting/receiving the program change messages used to change patterns. |
Key Velocity | vELo | 1–127 | Sets the velocity that’s generated when you press one of the sample pads [1]–[6] or the keyboard buttons on this unit. |
Velocity Curve | v.Crv | Sets how the volume changes according to velocity. | |
Tune | tUnE | 433.0–448.0 | Sets the master tuning. Default value: 440.0 Hz |
Ext. In Bus Select | In.b | This sets the output bus used for the signals that are input (including the built-in mic, the headset mic and signals input to the MIX IN jack). | |
bUS.A | Signals are output to BUS A. | ||
bUS.b | Signals are output to BUS B. | ||
EFCt | Signals are output to BUS EFFECT. | ||
Ext. In Gain | In.G | 0–18 (dB) | This sets the gain of the signals that are input (including the built-in mic, the headset mic and signals input to the MIX IN jack). |
USB In Bus Select | USb.b | Sets the output bus for signals inputted to the USB port. | |
bUS.A | Signals are output to BUS A. | ||
bUS.b | Signals are output to BUS B. | ||
EFCt | Signals are output to BUS EFFECT. | ||
USB In Gain | USb.G | 0–18 (dB) | Sets the gain for signals input to the USB port. |
Mix Out Gain | Out.G | -18–0 (dB) | Sets the MIX OUT jack gain. |
USB Direct Out | USb.d | Sets the volume of the signal output to the USB port. | |
OFF | Uses the [VOLUME] knob’s setting. | ||
1–127 | Sets the volume without regard to the [VOLUME] knob setting. | ||
AIRA Link | A.LnK | OFF, On | Set this to “On” when connecting a device via USB that is compatible with AIRA LINK, such as the MX-1. Otherwise, leave this at the OFF setting. The setting takes effect after the unit is powered off and on again. MEMO When using with another port besides the USB HOST 3 port on the MX-1, set the P-6 to “battery-only mode”. |
Count In | Cnt.I | OFF, 2–4 | Sets the length (the number of beats) of the count-in for recording. |
Metronome | ÷tro | Sets whether and when the metronome plays. | |
OFF | Always off | ||
rEC (Rec) | Turns on only when recording | ||
rC.PL (Rec&Play) | Turns on during recording and playback | ||
Metronome Level | ÷tr.L | 0–100 | Specifies the volume of the metronome. |
Dimmer (*2) | di÷r | This sets the illumination used when the following buttons are OFF.
| |
OFF | The buttons go dark. | ||
On | The buttons light up dimly. This improves the visibility of the buttons in dimly lit places. | ||
Reload Pattern | rL.Pt | Restores the selected pattern’s settings to the last saved state. Press the [C´] (ENTER) button to restore the settings. | |
Reload Granular | rL.Gr | Restores the granular sampler settings for the selected pattern to the last saved state. Press the [C´] (ENTER) button to restore the settings. | |
Reload Sequencer | rL.Sq | Restores the sequence of the selected pattern to its last saved state. Press the [C´] (ENTER) button to restore the settings. | |
Reload Pad | rL.Pd | Restores the settings for the selected sample pad to their last saved state. Press the [C´] (ENTER) button to restore the settings. | |
Initialize Pattern | It.Pt | Initializes the selected pattern. Press the [C´] (ENTER) button to initialize the pattern. | |
Initialize System | It.Sy | Initializes the system settings. Press the [C´] (ENTER) button to initialize the settings. (This excludes the parameters listed in *1.) | |
Initialize Effects | It.FX | Initializes the effect parameters. Press the [C´] (ENTER) button to initialize the parameters. |
- This is set to the current selected pattern (and can be saved for each pattern).
- Enabled as of ver. 1.02 and later.