DD-2
The DD-2 is the first digital long delay in a compact effect unit format. Delay times (12.5–800 msec) and frequency characteristics (40 Hz–7 kHz, +1/-3 dB) that were unheard of in previous compact analog delays are now possible. |
Page | Parameter | Value | Explanation |
---|---|---|---|
1 | E.LEVEL | 0–100 | Adjusts the volume when the effect is used. When this is set to maximum, the delay and direct sounds are the same volume. When this is set to minimum, only the normal sound is output when connecting in mono, and the output from the main outs is set to “0” when connecting in stereo. |
F.BACK | 0–100 | Adjusts the delay repeats. | |
D.TIME | 0–100, BPM | Fine-tunes the delay time. The delay time changes continuously from 0.25 to 1 time the value set for the mode.
| |
2 | MODE | S.50ms, M.200ms, L.800ms, HOLD | Switches the mode. In HOLD mode, you can use the D.TIME setting to change the hold time within a range of 200–800 msec. |
BPM | 40–250 | Adjusts the tempo if “BPM” is selected for D.TIME.
| |
CARRYOVER | OFF, ON | Specifies whether the effect sound is carried over (ON) or not carried over (OFF) when you turn off the effect. | |
3 | OUTPUT | STEREO, DRY/EFFECT | Specifies the output mode. STEREO: The direct (dry) sound is mixed with the effect (wet) sound, and output from the OUTPUT A (MONO) and OUTPUT B jacks. DRY/EFFECT: The effect (wet) sound is output from the OUTPUT A (MONO) jack, and the direct (dry) sound is output from the OUTPUT B jack. |
– | – |
| |
– | – |
| |
4 | CTL1 TARGET | OFF, E.LEVEL, F.BACK, D.TIME, TAP | Selects the parameter to control from a footswitch connected to CTL1. The TIME range for the tap operation is 133–800 ms. The BPM range is 70–300.
|
CTL1 MODE | MOMENT, TOGGLE | Selects the operation mode for the footswitch that’s connected to CTL1.
| |
CTL1 VALUE | 0–100, BPM | Sets the value for the parameter that’s controlled from a footswitch connected to CTL1.
| |
5 | CTL2 TARGET | OFF, E.LEVEL, F.BACK, D.TIME, TAP | Selects the parameter to control from a footswitch connected to CTL2. The TIME range for the tap operation is 133–800 ms. The BPM range is 70–300.
|
CTL2 MODE | MOMENT, TOGGLE | Selects the operation mode for the footswitch connected to CTL2.
| |
CTL2 VALUE | 0–100, BPM | Selects the value for the parameter that’s controlled from a footswitch connected to CTL2.
| |
6 | EXP TARGET | OFF, E.LEVEL, F.BACK, D.TIME | Sets the parameter controlled by an expression pedal connected to EXP. |
EXP MIN | 0–100, BPM | Sets the minimum value for the parameter controlled by an expression pedal connected to EXP. | |
EXP MAX | 0–100, BPM | Sets the maximum value for the parameter controlled by an expression pedal connected to EXP. | |
7 | PEDAL MODE | MOMENT, TOGGLE | Selects the operation mode for the pedal switch on the PX-1.
|
ACTION | OFF Ó ON, ON Ó OFF | Sets how the pedal switch on this unit operates when PEDAL MODE is set to “MOMENT”. | |
– | – |
|