Parameter Value Explanation
RX CHANNEL This sets the MIDI channel used for receiving MIDI messages.
CH1–CH16 Specifies the receive channel.
TX CHANNEL Sets the MIDI channel used for transmitting MIDI messages.
CH1–CH16 Specifies the transmit channel.
RX CH Transmits on the same channel as the RX CHANNEL.
MIDI IN THRU This specifies the connector from which to output the MIDI messages that are received at the MIDI IN connector.
OFF MIDI messages are not transmitted.
MIDI OUT Messages are transmitted from the MIDI OUT connector.
USB OUT Messages are transmitted from the USB port.
USB & MIDI Output from the USB port and the MIDI OUT connector.
USB IN THRU This specifies the connector from which to output the MIDI messages that are received at the USB port.
OFF MIDI messages are not transmitted.
MIDI OUT Messages are transmitted from the MIDI OUT connector.
USB OUT Messages are transmitted from the USB port.
USB & MIDI Output from the USB port and the MIDI OUT connector.
SYNC CLOCK

This setting determines the basis used for synchronizing the timing for effect modulation rates and other time-based parameters.

  • When you have an external MIDI device connected, the MASTER BPM is then synchronized to the external MIDI device’s tempo, thus disabling the MASTER BPM setting. To enable setting of the MASTER BPM, set to “INTERNAL”.
  • When synchronizing performances to the MIDI Clock signal from an external MIDI device, timing problems in the performance may occur due to errors in the MIDI Clock.
AUTO

Operations are synchronized to MIDI clock messages received via MIDI or USB. However, operations are automatically synchronized to the GX-100’s internal clock if the GX-100 is unable to receive the external Clock.

INTERNAL

Operations are synchronized to the GX-100’s internal Clock.

MIDI (AUTO)

Operations are synchronized to the MIDI Clock received via MIDI. However, operations are automatically synchronized to the GX-100’s internal clock if the GX-100 is unable to receive the external Clock.

USB (AUTO)

Operations are synchronized to the USB Clock received via USB. However, operations are automatically synchronized to the GX-100’s internal clock if the GX-100 is unable to receive the external Clock.

CLOCK OUT


Specifies whether MIDI clock will be output from the GX-100.

OFF MIDI clock is not output.
ON MIDI clock is output.

NUM1 CC#

NUM2 CC#

NUM3 CC#

NUM4 CC#

BANK á CC#

BANK à CC#

EXP1 SW CC#

CTL1 CC#

CTL2 CC#

CTL3 CC#

CTL4 CC#

EXP1 CC#

EXP2 CC#

Specifies the controller number when transmitting pedal operations as control change messages.
OFF Control Change messages are not output.

CC#1–CC#31,

CC#64–CC#95

Pedal operations are transmitted using the specified controller number.