1. Select [MENU] Ó “KIT EDIT2”.
  2. Use the cursor [à] [á] [ã] [â] buttons to select “KIT MIDI” and press the [ENTER] button.

    Use the function buttons to select the parameters.

    Controller

    Explanation

    Cursor [à] [á] [ã] [â] button

    Selects the pads.

    [-] [+] buttons, [VALUE] knob

    Sets the value.



Assigning a note number to a pad (NOTE NO.)

Here’s how to set the note numbers that are transmitted and received from the MIDI connectors.

Parameter

Value

Explanation

NOTE NO.

0 (C-)–127 (G9), OFF

Sets the MIDI note number that’s transmitted/received for each pad, TRIGGER IN, FOOT SW and for the hi-hat closed pedal operation.

When this is set to “OFF”, note messages are not transmitted or received.


Setting the gate time (GATE TIME)

This shows how to set the length (gate time) of the notes that sound.

Parameter

Value

Explanation

GATE TIME

0.1–8.0

Sets how long the notes play that are transmitted by each pad, TRIGGER IN and FOOT SW.


Setting the MIDI channel (CHANNEL)

Parameter

Value

Explanation

CHANNEL

CH 1–16, GLOBAL

Sets the MIDI channel used to transmit/receive note and control change messages for each pad, TRIGGER IN and FOOT SW.
When this is set to “GLOBAL”, the channel specified in the SYSTEM MIDI “Global MIDI Channel” settings is used for transmitting/receiving.


Configuring the settings for each pad to play external devices (EXT CTRL)

Parameter

Value

Explanation

EXT CTRL

OFF, ON,

ON-ALT

When this is set to “ON” and you strike a pad, the note is transmitted according to the GATE TIME settings, and you can play external devices without producing sound on this unit.
When this is set to “ON-ALT” and you strike a pad, the note alternately switches between note-on and note-off according to how hard you strike the pad, and you can play external devices without producing sound on this unit.


Restoring the default settings (DEFAULT)

Here’s how to restore the settings to their default values.

  1. Press the [F6] (DEFAULT) button.

    A confirmation message appears.


  2. Use the cursor [ã] [â] buttons to select “OK”, and press the [ENTER] button.

    After “Completed!” appears, the display returns to the previous screen.